{"id":23035,"date":"2026-11-27T10:00:23","date_gmt":"2026-11-27T13:00:23","guid":{"rendered":"https:\/\/www.grupoacocearense.com.br\/?p=23035"},"modified":"2026-08-25T13:50:09","modified_gmt":"2026-08-25T16:50:09","slug":"tela-soldada-pisos","status":"publish","type":"post","link":"https:\/\/www.grupoacocearense.com.br\/en\/tela-soldada-pisos\/","title":{"rendered":"Welded wire mesh in industrial flooring: how to use"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">THE <\/span><b>welded wire mesh in industrial flooring<\/b><span style=\"font-weight: 400;\"> It reinforces the concrete slab and helps control crack opening. However, its performance depends on the dimensions, the position within the slab, and the execution of the joints.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The floor also needs a stable subgrade, a prepared base, concrete compatible with the loads, and proper curing. The mesh does not correct flaws in these steps.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Therefore, the steel grade, wire diameter, mesh spacing, splices, and cover must follow the design. Choosing the most well-known model or the lowest price can lead to waste and compromise execution.<\/span><\/p>\n<h2><b>What is welded wire mesh for concrete?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Welded wire mesh is a prefabricated reinforcement composed of longitudinal and transverse steel wires. The wires are joined by welding at regular points, forming a mesh with standardized dimensions.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This configuration reduces spacing variations found in wire-by-wire assembled reinforcements. Furthermore, it facilitates the placement of the reinforcement in large areas.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Screens intended for concrete must meet the following requirements: <\/span><b>ABNT NBR 7481:2022, Corrected Version 2:2023<\/b><span style=\"font-weight: 400;\">. The standard establishes requirements for ribbed welded steel mesh used as reinforcement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In civil construction, the material appears in slabs, walls, pre-cast elements, pavements, and floors. Our content about<\/span><a href=\"https:\/\/www.grupoacocearense.com.br\/en\/telas-soldadas-versatilidade-e-resistencia-para-a-construcao-civil\/\"> <span style=\"font-weight: 400;\">welded wire mesh in civil construction<\/span><\/a><span style=\"font-weight: 400;\"> It has other applications.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In industrial flooring, the function of the mesh depends on the calculations. It can act in controlling cracking or contribute to the slab&#039;s resistance, according to the solution defined by the designer.<\/span><\/p>\n<h2><b>Why do industrial floors require a specific design?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An industrial floor is subjected to different stresses than a residential subfloor. Forklifts, trucks, machinery, and storage structures apply loads with their own intensities and shapes.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A pallet rack, for example, concentrates forces on small support points. A forklift, on the other hand, transmits repeated loads through its wheels and aisles.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">There are also distributed loads, impacts, vibrations, and temperature changes. Therefore, the design needs to consider the activity that will be carried out on the site.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Industrial flooring functions as a <\/span><b>system consisting of soil, base, concrete slab, joints and finishing.<\/b><span style=\"font-weight: 400;\">. If one of these parts malfunctions, the others may lose performance.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">IBRACON emphasizes this systemic view by treating the foundation soil, sub-base, slab, and pavement as interdependent parts of the pavement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Therefore, simply defining the concrete thickness and the mesh design is not enough. Loads, soil type, and usage pattern must be factored into the design.<\/span><\/p>\n<h2><b>What is the function of welded wire mesh in flooring?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The mesh forms a distributed reinforcement in both directions of the plate. This feature helps to keep the steel organized over large areas.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">One of its most common functions is to control the opening of cracks. Concrete undergoes shrinkage during drying and movements caused by temperature changes.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The reinforcement does not completely prevent these movements. However, it can limit the opening of cracks when it is sized and positioned according to the design.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In some flooring systems, the membrane also contributes to tensile strength. This function needs to be calculated based on the membrane thickness, the loads, and the support provided by the ground.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Therefore, we should not assume that any screen automatically increases the floor&#039;s capacity. <\/span><b>The result depends on the quantity and position of the steel.<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Proper application still requires planned joints and concrete curing. Without these precautions, the floor can crack even with a heavier mesh.<\/span><\/p>\n<h2><b>Does welded wire mesh eliminate cracks?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">No. Welded wire mesh helps control cracking, but it does not eliminate all causes of cracks in concrete floors.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Shrinkage begins when concrete loses water and reduces its volume. If the slab encounters restrictions, internal stresses can cause cracking.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Temperature differences also cause floor movement. Areas exposed to sunlight, cold storage rooms, and areas near heated equipment require attention.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Other causes include poorly compacted soil, uneven thickness, excess water in the mixture, insufficient curing, and joints installed outside of the specified timeframe.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In these cases, increasing the amount of steel without addressing the root of the problem may not produce the desired result.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The screen acts primarily in <\/span><b>distribution of reinforcement and control of crack opening<\/b><span style=\"font-weight: 400;\">. The joint design should direct some of these movements to designated locations.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Therefore, prevention depends on the combination of reinforcement, concrete, foundation, joints, and execution.<\/span><\/p>\n<h2><b>What loads should be evaluated?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The lifting of loads needs to reflect future operations. An empty warehouse during construction can accommodate heavy equipment after completion.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The designer must know the weight of the machines, the configuration of the stock, and the vehicles that will circulate in the area.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Among the most common requests are:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Point loads:<\/b><span style=\"font-weight: 400;\"> Machine feet, shelves, and storage structures concentrate stress in small areas. The position of these supports must be compared to the joints and edges of the panel.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Mobile cargo:<\/b><span style=\"font-weight: 400;\"> Forklifts, pallet jacks, and trucks apply repeated forces. Weight per axle, wheel type, and frequency of passage alter the stress.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Distributed loads:<\/b><span style=\"font-weight: 400;\"> Materials stored directly on the floor spread their weight over larger areas. The actual distribution depends on the type of support.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Impacts and vibrations:<\/b><span style=\"font-weight: 400;\"> Falling objects, machinery, and ongoing operations may require specific reinforcement and insulation measures.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">The screen should not be chosen solely based on the total weight moved within the property. Geometry, frequency, and application point also affect the sizing.<\/span><\/p>\n<h2><b>Which areas can be fitted with welded wire mesh?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The screen can be specified for different concrete floors and pavements. The model and position change according to the function of the location:\u00a0<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Industrial warehouses are among the best-known applications. In these, the structural design needs to take into account machinery, inventory, and internal movement.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Logistics centers experience repeated forklift traffic and concentrated loads on the racks. Therefore, the mapping of aisles and structures must be provided to the designer.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Parking lots can also use welded wire mesh. In this case, the calculations include vehicles, ramps, maneuvering areas, and exposure to the elements.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cargo yards receive trucks, trailers, and larger impacts. The solution may require transfer bars, localized reinforcements, or other configurations in addition to the screen.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High-traffic commercial areas, supermarket floors, and reinforced sidewalks can also utilize the material. However, the choice should be based on the load and support conditions.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">On our page<\/span><a href=\"https:\/\/www.grupoacocearense.com.br\/en\/produtos\/\"> <span style=\"font-weight: 400;\">products for civil construction<\/span><\/a><span style=\"font-weight: 400;\">, We offer screens, meshes, and other reinforcements designed for concrete.<\/span><\/p>\n<h2><b>How do I choose the right screen model?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The selection takes into account wire diameter, spacing, amount of steel per direction, and panel dimensions. This information must be included in the design and order.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Commercial wire meshes are designated as Q61, Q92, Q138, and Q196. Each code represents a specific wire configuration and steel area.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, the number should not be used as an automatic indication for a type of flooring. A Q138 screen may be suitable for a particular project and insufficient or excessive for another.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The mesh can also have different spacing between the wires. Smaller spaces distribute more steel points, but alter weight, consumption, and performance.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The diameter affects the steel area and the panel&#039;s rigidity. Furthermore, it influences handling and behavior during concreting.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Before purchasing, we recommend checking the <\/span><b>full screen designation<\/b><span style=\"font-weight: 400;\">, the panel dimensions and the project review.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Customers in Cear\u00e1 can view models in the category of<\/span><a href=\"https:\/\/loja.grupoacocearense.com.br\/construcao-civil\/telas-e-malhas\"> <span style=\"font-weight: 400;\">fabrics and meshes from our store<\/span><\/a><span style=\"font-weight: 400;\">, without replacing the technical validation from engineering.<\/span><\/p>\n<h2><b>What is the relationship between the screen and the CA-60?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Ribbed welded wire mesh used in concrete structures is produced with steel wires that must meet applicable requirements.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">CA-60 is commonly used in this manufacturing process. Its strength class, adhesion, and regularity allow for the production of standardized reinforcements.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, the buyer must check the complete product. It is not enough to know that the wires are CA-60, as the diameter, spacing, and steel area must also match the project specifications.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The quality of the welded points deserves the same attention. They maintain the geometry of the mesh during transport, positioning, and concreting.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Our content about<\/span><a href=\"https:\/\/www.grupoacocearense.com.br\/en\/vergalhao-ca-60\/\"> <span style=\"font-weight: 400;\">CA-60 steel requirements<\/span><\/a><span style=\"font-weight: 400;\"> It explains the characteristics of this category and its applications in armor.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Identifying the manufacturer, batch, and screen helps maintain traceability. This information should remain available until the material is inspected.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">At Sinobras, we produce long steel products for the construction industry. At A\u00e7o Cearense Comercial, we distribute screens and meshes for different types of construction projects.<\/span><\/p>\n<h2><b>Why does the type of flooring affect the final result?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The concrete slab transfers loads to the layers located below it. When the support fails, unforeseen deformations and stresses arise.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The subgrade must have bearing capacity and compaction compatible with the project. Soils with weak points can generate localized settlement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A sub-base helps to even out the support and can aid in drainage, depending on the solution adopted. Thickness, material, and degree of compaction must be controlled.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">It is also necessary to correct holes, unevenness, and areas with loose material before pouring the concrete. An uneven base produces variations in the thickness of the slab.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Under these conditions, the screen alone cannot compensate for the loss of support. The floor may have uneven surfaces, cracks, or broken edges.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">When the design calls for a vapor barrier, tarp, or slip layer, these components must be installed without improper folds.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The technical analysis of industrial floors published by IBRACON reinforces that performance depends on the overall system, and not just the concrete or the reinforcement.<\/span><\/p>\n<h2><b>Where should the screen be placed on the board?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The position of the screen is determined according to the function of the reinforcement. Therefore, it should not be left directly on the ground or on the tarp.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">When the mesh remains at the bottom of the slab without proper technical planning, it may lose some of its ability to control cracks near the surface.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">It is also not advisable to support the screen on the ground and lift it manually during concreting. This method results in uneven heights and does not allow for checking the final position.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The correct thing to do is to use <\/span><b>spacers compatible with the load of the armor and the team<\/b><span style=\"font-weight: 400;\">. They must keep the screen at the indicated height without tipping it over.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The distance from the surface, edges, and joints depends on the design. There is no single measurement that applies to all floors.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The DER-SP technical specification for concrete pavements, for example, determines that the type and position of the mesh must be defined in the project.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Before pouring the concrete, the inspection team must measure the height at different points. They also need to verify that the spacers are distributed sufficiently.<\/span><\/p>\n<h2><b>How do I perform the overlays?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The panels need to maintain continuity at the points where they meet. To achieve this, the project defines overlaps, joints, or another connection method.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The width of the splice should not be chosen solely based on the team&#039;s experience. Wire diameter, spacing, and stress all influence the required length.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Overlaps that are smaller than planned can disrupt the continuity of the reinforcement. Excessive splices, on the other hand, increase steel consumption and make concreting more difficult.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The screens must be secured to prevent displacement. Ties can keep the panels aligned during team movement and concrete pouring.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">At the edges, pillars, boxes, and openings, the design may require cutouts or reinforcements. Simply interrupting the grid can concentrate cracks at these points.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Cuts should be planned before installation. Burrs and exposed edges need to be treated to avoid injuring the team or altering the coating.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">When there are two layers of screen, each needs its own spacers and positioning. This configuration should be clearly shown in the drawings.<\/span><\/p>\n<h2><b>What is the role of joints in industrial flooring?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The joints organize the floor&#039;s movements and divide large areas into smaller slabs. They also separate stages of concreting and elements that move differently.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Contraction joints create planned locations for crack opening. The cut needs to reach a depth and timeframe defined by the project.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Construction joints appear between concrete pouring stages. They may incorporate dowel bars or other devices to maintain alignment between slabs.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Isolation joints separate the floor from pillars, walls, machine bases, and other fixed elements.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The welded wire mesh should not span all joints without analysis. In some places, the reinforcement is interrupted. In others, the design defines continuity or specific reinforcement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Transfer bars cannot be replaced by the screen either. They have a specific function in transmitting charges between plates.<\/span><\/p>\n<p><b>Screen, joints, and transfer bars serve different functions.<\/b><span style=\"font-weight: 400;\">. The execution must follow the detailed plan for each meeting.<\/span><\/p>\n<h2><b>How does concrete affect screen performance?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The reinforcement works in conjunction with the concrete. Therefore, the strength, consistency, and homogeneity of the mixture affect the entire floor.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Adding water to the construction site without control alters the water-cement ratio. This can increase shrinkage, reduce strength, and promote surface wear.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The application process must also avoid segregation. Concentrated aggregates and areas with excess paste create variations within the slab.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">During compaction, the team needs to fill the spaces around the wires. Voids near the reinforcement compromise the adhesion and protection of the steel.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The thickness of the board must remain uniform. Variations can create weak zones, even when the amount of screen is correct.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The surface finish needs to respect the concrete&#039;s natural state. Working the surface with added water or paste can result in a weak layer.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The construction of concrete structures must observe the <\/span><b>ABNT NBR 14931:2023<\/b><span style=\"font-weight: 400;\">, in addition to the project specifications and the technological controls planned for the work.<\/span><\/p>\n<h2><b>Why is concrete curing essential?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Curing reduces the rapid loss of water during the early stages of concrete formation. Without this control, the surface dries before the interior, creating stresses.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This process can cause plastic cracking, wear, and reduced surface quality. The screen does not prevent these problems when curing is neglected.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The method should be defined according to the area, climate, and finish. Curing products, wet blankets, or other specified systems may be used.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Wind, heat, and low humidity accelerate evaporation. Floors installed under these conditions require planning to protect the surface immediately after finishing.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The circulation of people, machinery, and vehicles should only occur after the necessary resistance has been established. Releasing the floor too early can damage joints, edges, and the finish.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">We also need to preserve the healing process in the areas surrounding the cuts. The jointing process should not leave the surface unprotected.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The inspection should record the time of concrete pouring, curing method, and weather conditions. This data helps analyze any potential problems that may arise later.<\/span><\/p>\n<h2><b>How to install a welded screen correctly?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The installation must follow a sequence that preserves the position, continuity, and cleanliness of the reinforcement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The process can be organized into these steps:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Check the documents:<\/b><span style=\"font-weight: 400;\"> Validate the project review, screen model, joints, reinforcements, and levels before starting the service.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Prepare the support:<\/b><span style=\"font-weight: 400;\"> Compact and level the layers of the floor, installing tarpaulins or barriers as planned.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Distribute the spacers:<\/b><span style=\"font-weight: 400;\"> Position supports capable of maintaining the screen at the indicated height during concreting.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Assembling the panels:<\/b><span style=\"font-weight: 400;\"> Respect the direction, overlaps, edges, cutouts, and reinforcements defined in the drawings.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Fix and inspect:<\/b><span style=\"font-weight: 400;\"> Tie the ends together and measure the position of the reinforcement at various points.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>To finalize without moving the screen:<\/b><span style=\"font-weight: 400;\"> Organize circulation, launch, and densification to preserve the installation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Perform healing and joints:<\/b><span style=\"font-weight: 400;\"> to meet the deadlines, depths and methods planned for the floor.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Inspecting before pouring concrete prevents the need for corrections after the reinforcement is covered.<\/span><\/p>\n<h2><b>What are the most common errors during execution?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A common mistake is choosing a tile based on a previous installation. Similar tiles can withstand different loads, soil types, and joints.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Another problem occurs when the panels are placed directly on the base. In this position, the reinforcement may not perform its calculated function.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Insufficient overlaps also create discontinuity. Conversely, excessive splices consume steel and create congested areas.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Walking on the mesh without proper support can deform the panels and knock down the spacers. Pouring concrete can also displace the mesh.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Cutting the mesh around pillars without installing the planned reinforcements concentrates stress. The same occurs in drains, boxes, and equipment bases.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Joints installed late or in different locations than planned increase the risk of random cracking.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Finally, the lack of curing compromises the surface and increases shrinkage. No amount of reinforcement can correct all these deviations after the concrete has been poured.<\/span><\/p>\n<h2><b>How do I receive and store the screens?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The conference begins with a comparison between the order, the design, and the material identification. Designation, diameter, spacing, and dimensions must match.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The panels must arrive without any deformities that could hinder assembly. Broken weld points and displaced wires need to be documented.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The batch identification must remain legible. It links the material to the supplier&#039;s documents and controls.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">During storage, the screens need to be kept off the ground. Distributed supports prevent warping and contact with standing water.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The models must be kept separate to prevent mix-ups. A building may receive visually similar screens, but with different steel areas.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Our guide on<\/span><a href=\"https:\/\/www.grupoacocearense.com.br\/en\/conheca-as-melhores-praticas-de-armazenamento-de-aco\/\"> <span style=\"font-weight: 400;\">proper storage of steel<\/span><\/a><span style=\"font-weight: 400;\"> It provides guidelines for organizing materials on the construction site.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Before use, the team must remove mud, oil, or substances that could impair adhesion to the concrete. Any significant corrosion needs to undergo a technical evaluation.<\/span><\/p>\n<h2><b>How to check the quality of welded wire mesh?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The screen must have dimensions, wires, spacing, and welds consistent with its designation. This information must be included in the product documentation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Provenance allows for tracking of materials and verification of compliance with standards. Therefore, notes, labels, and reports must be kept organized.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Visual inspection verifies deformations, broken wires, welding defects, and contamination. When the project requires it, tests and certificates may also be requested.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Our article about<\/span><a href=\"https:\/\/www.grupoacocearense.com.br\/en\/o-que-os-laudos-tecnicos-devem-garantir-na-qualidade-do-aco\/\"> <span style=\"font-weight: 400;\">technical reports for steel quality<\/span><\/a><span style=\"font-weight: 400;\"> It explains what information helps to confirm properties and compliance.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">At Grupo A\u00e7o Cearense, we maintain control processes for products intended for the construction industry. Purchases with clear identification facilitate receiving and reduce the risk of mix-ups.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, control doesn&#039;t end with the supplier. Transportation, storage, and assembly must preserve the screen until the concrete pouring process.<\/span><\/p>\n<h2><b>Choose canvases and meshes for your project.<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The use of welded wire mesh in industrial floors requires a design compatible with loads, soil, joints, and concrete. The correct choice avoids unnecessary consumption and reduces defects during installation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">At A\u00e7o Cearense Comercial, we distribute screens and meshes for floors, slabs, and other concrete structures. Our portfolio serves construction companies, industries, distributors, and construction professionals.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">To view available models, dimensions, and products,<\/span><a href=\"https:\/\/conteudos.grupoacocearense.com.br\/baixe-nosso-catalogo\"> <span style=\"font-weight: 400;\">Download our catalog.<\/span><\/a><span style=\"font-weight: 400;\"> and send the project specifications for a quote.<\/span><\/p>\n<h2><b>Frequently asked questions about screens on floors<\/b><\/h2>\n<h3><b>What is the difference between welded wire mesh and pop mesh?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Both products feature crossed and welded wires. However, dimensions, diameters, spacing, and applications may vary. The design should specify the product compatible with the structural function.<\/span><\/p>\n<h3><b>Is it possible to cut a welded wire mesh on the construction site?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Yes, when cuts are planned in the detailing. The team must preserve overlaps, coverings, and reinforcements around pillars, boxes, and openings.<\/span><\/p>\n<h3><b>Can an industrial floor use two layers of mesh?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Yes, provided that configuration has been properly dimensioned. Each layer needs to remain in the indicated position, with adequate spacers and sufficient distance for concreting.<\/span><\/p>\n<h3><b>Does slight oxidation prevent the screen from being used?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">There is no single answer. The responsible technician must check for loss of section, scaling, and contamination. Mud, oil, and loose rust need to be removed before concreting.<\/span><\/p>\n<h3><b>When can vehicles drive on the new pavement?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The release time depends on the strength achieved by the concrete and the conditions defined in the project. The timeframe should not be determined solely by the dry appearance of the surface.<\/span><\/p>\n<h3><b>Can the screen be used to secure pipes in the floor?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The reinforcement should not be modified in a way that alters its position. Pipes, conduits, and inserts require their own supports and details, defined before concreting.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Welded wire mesh in industrial floors reinforces the concrete slab and helps control(\u2026)<\/p>","protected":false},"author":8,"featured_media":23036,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[6],"tags":[],"class_list":["post-23035","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-produtos"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.6 (Yoast SEO v28.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Tela soldada em pisos industriais: como usar - Grupo A\u00e7o Cearense<\/title>\n<meta name=\"description\" content=\"Entenda como usar tela soldada em pisos industriais, desde a especifica\u00e7\u00e3o e o posicionamento at\u00e9 a concretagem e o controle de fissuras.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.grupoacocearense.com.br\/en\/tela-soldada-pisos\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tela soldada em pisos industriais: como usar\" \/>\n<meta property=\"og:description\" content=\"Entenda como usar tela soldada em pisos industriais, desde a especifica\u00e7\u00e3o e o posicionamento at\u00e9 a concretagem e o controle de fissuras.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.grupoacocearense.com.br\/en\/tela-soldada-pisos\/\" \/>\n<meta property=\"og:site_name\" content=\"Grupo A\u00e7o Cearense\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-27T13:00:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.grupoacocearense.com.br\/wp-content\/uploads\/2026\/07\/image1-7.png\" \/>\n\t<meta property=\"og:image:width\" content=\"863\" \/>\n\t<meta property=\"og:image:height\" content=\"551\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Samuel Faria\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Samuel Faria\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"19 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/\"},\"author\":{\"name\":\"Samuel Faria\",\"@id\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/#\\\/schema\\\/person\\\/7ccebb269b40e44958dadd1a0f2e91db\"},\"headline\":\"Tela soldada em pisos industriais: como usar\",\"datePublished\":\"2026-11-27T13:00:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/\"},\"wordCount\":3681,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/image1-7.png\",\"articleSection\":[\"Produtos\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/\",\"url\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/\",\"name\":\"Tela soldada em pisos industriais: como usar - Grupo A\u00e7o Cearense\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/image1-7.png\",\"datePublished\":\"2026-11-27T13:00:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/#\\\/schema\\\/person\\\/7ccebb269b40e44958dadd1a0f2e91db\"},\"description\":\"Entenda como usar tela soldada em pisos industriais, desde a especifica\u00e7\u00e3o e o posicionamento at\u00e9 a concretagem e o controle de fissuras.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/image1-7.png\",\"contentUrl\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/image1-7.png\",\"width\":863,\"height\":551},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/tela-soldada-pisos\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tela soldada em pisos industriais: como usar\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/#website\",\"url\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/\",\"name\":\"A\u00e7o Cearense\",\"description\":\"H\u00e1 mais de 45 anos no mercado brasileiro do a\u00e7o.\",\"alternateName\":\"A\u00e7o Cearense\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/previews.elleven.digital\\\/acocearense\\\/#\\\/schema\\\/person\\\/7ccebb269b40e44958dadd1a0f2e91db\",\"name\":\"Samuel Faria\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/10f596d407bb437dafc6974c4cd236a54f3393f16fca92011ac3ea64102e2b3b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/10f596d407bb437dafc6974c4cd236a54f3393f16fca92011ac3ea64102e2b3b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/10f596d407bb437dafc6974c4cd236a54f3393f16fca92011ac3ea64102e2b3b?s=96&d=mm&r=g\",\"caption\":\"Samuel Faria\"},\"url\":\"https:\\\/\\\/www.grupoacocearense.com.br\\\/en\\\/author\\\/samuel-faria\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Tela soldada em pisos industriais: como usar - Grupo A\u00e7o Cearense","description":"Entenda como usar tela soldada em pisos industriais, desde a especifica\u00e7\u00e3o e o posicionamento at\u00e9 a concretagem e o controle de fissuras.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.grupoacocearense.com.br\/en\/tela-soldada-pisos\/","og_locale":"en_US","og_type":"article","og_title":"Tela soldada em pisos industriais: como usar","og_description":"Entenda como usar tela soldada em pisos industriais, desde a especifica\u00e7\u00e3o e o posicionamento at\u00e9 a concretagem e o controle de fissuras.","og_url":"https:\/\/www.grupoacocearense.com.br\/en\/tela-soldada-pisos\/","og_site_name":"Grupo A\u00e7o Cearense","article_published_time":"2026-11-27T13:00:23+00:00","og_image":[{"width":863,"height":551,"url":"https:\/\/www.grupoacocearense.com.br\/wp-content\/uploads\/2026\/07\/image1-7.png","type":"image\/png"}],"author":"Samuel Faria","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Samuel Faria","Est. reading time":"19 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#article","isPartOf":{"@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/"},"author":{"name":"Samuel Faria","@id":"https:\/\/previews.elleven.digital\/acocearense\/#\/schema\/person\/7ccebb269b40e44958dadd1a0f2e91db"},"headline":"Tela soldada em pisos industriais: como usar","datePublished":"2026-11-27T13:00:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/"},"wordCount":3681,"commentCount":0,"image":{"@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#primaryimage"},"thumbnailUrl":"https:\/\/www.grupoacocearense.com.br\/wp-content\/uploads\/2026\/07\/image1-7.png","articleSection":["Produtos"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/","url":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/","name":"Tela soldada em pisos industriais: como usar - Grupo A\u00e7o Cearense","isPartOf":{"@id":"https:\/\/previews.elleven.digital\/acocearense\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#primaryimage"},"image":{"@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#primaryimage"},"thumbnailUrl":"https:\/\/www.grupoacocearense.com.br\/wp-content\/uploads\/2026\/07\/image1-7.png","datePublished":"2026-11-27T13:00:23+00:00","author":{"@id":"https:\/\/previews.elleven.digital\/acocearense\/#\/schema\/person\/7ccebb269b40e44958dadd1a0f2e91db"},"description":"Entenda como usar tela soldada em pisos industriais, desde a especifica\u00e7\u00e3o e o posicionamento at\u00e9 a concretagem e o controle de fissuras.","breadcrumb":{"@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#primaryimage","url":"https:\/\/www.grupoacocearense.com.br\/wp-content\/uploads\/2026\/07\/image1-7.png","contentUrl":"https:\/\/www.grupoacocearense.com.br\/wp-content\/uploads\/2026\/07\/image1-7.png","width":863,"height":551},{"@type":"BreadcrumbList","@id":"https:\/\/www.grupoacocearense.com.br\/tela-soldada-pisos\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/www.grupoacocearense.com.br\/"},{"@type":"ListItem","position":2,"name":"Tela soldada em pisos industriais: como usar"}]},{"@type":"WebSite","@id":"https:\/\/previews.elleven.digital\/acocearense\/#website","url":"https:\/\/previews.elleven.digital\/acocearense\/","name":"Cear\u00e1 Steel","description":"In the Brazilian steel market for over 45 years.","alternateName":"A\u00e7o Cearense","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/previews.elleven.digital\/acocearense\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/previews.elleven.digital\/acocearense\/#\/schema\/person\/7ccebb269b40e44958dadd1a0f2e91db","name":"Samuel Faria","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/10f596d407bb437dafc6974c4cd236a54f3393f16fca92011ac3ea64102e2b3b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/10f596d407bb437dafc6974c4cd236a54f3393f16fca92011ac3ea64102e2b3b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/10f596d407bb437dafc6974c4cd236a54f3393f16fca92011ac3ea64102e2b3b?s=96&d=mm&r=g","caption":"Samuel Faria"},"url":"https:\/\/www.grupoacocearense.com.br\/en\/author\/samuel-faria\/"}]}},"_links":{"self":[{"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/posts\/23035","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/comments?post=23035"}],"version-history":[{"count":1,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/posts\/23035\/revisions"}],"predecessor-version":[{"id":23037,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/posts\/23035\/revisions\/23037"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/media\/23036"}],"wp:attachment":[{"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/media?parent=23035"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/categories?post=23035"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.grupoacocearense.com.br\/en\/wp-json\/wp\/v2\/tags?post=23035"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}